Installation
Personal Protective Equipment (PPE) required
All work places differ with regards to the use of PPE. Please wear the appropriate PPE required by your locations working regulations.
(e.g. boiler suit, safety boots, safety gloves, hard hat, hearing protection, safety glasses, high visibility work vest)
Primary Surface/Structure |
Fixing Method |
Open grating/grille |
Scotgrip Type ‘S’ fixing (zinc plated or S/S)
(comprises of M8 bolt, adjustable u-clamp
& nyloc nut)
|
Steel/Aluminium plate |
M8 bolt, nyloc nut & washer (zinc plated or S/S)
Self tapping screw (zinc plated or S/S)
Adhesives – recommended by Scotgrip
|
Concrete |
Concrete hammer screw (galvanised or S/S)
(various sizes)
|
Timber |
Woodscrews (zinc plated or S/S) |
All fixings and adhesives are available ex-stock from Scotgrip (UK) Ltd.
Securing Scotgrip® anti-slip material to open grating/grille using Type ‘S’ fixings
- Place the anti-slip material in the position required.
- Put the bolt through the pre-drilled hole in the anti-slip material and through the grating/grille.
- Place the u-clamp on the underside of the grating/grille and through the bolt.
- Screw the nyloc nut onto the bolt and hand tighten it. Repeat this process with the remaining fixings on the piece of material you are working on to ensure all bolts have a proper seating.
- Place a socket wrench or spanner onto the nyloc nut and at the same time place a variable speed drill with appropriate screwdriver bit onto the dome head of the bolt, slowly tighten the nyloc nut ensuring that the u-clamp remains fitted to the underside of the grating/grille.
- Tighten the type ‘S’ fixing until the anti-slip material is securely fixed to the grating/grille.
Type ‘S’ fixings are available ex-stock from Scotgrip (UK) Ltd.
Securing Scotgrip® anti-slip material with concrete hammer screws
- Place the anti-slip material in the position required.
- Set-up drilling gauge to a depth of: 40mm (19/32") (HPS-1 6/5 x 30)
| |
50mm (2") (HPS-1 6/15 x 40) |
- Use a 6mm Ø (1/4" Ø) drill bit to drill holes in the concrete to the required depth.
- Insert the concrete hammer screw through the pre-drilled holes in the anti-slip and into the drilled hole in the concrete.
- Use a hammer to drive the fixings through, taking care not to damage the anti-slip surface.
- The anti-slip material should now be secure.
Concrete hammer screw types
- HPS-1 6/5 x 30 (30mm long) - (1 3/16" long)
- HPS-1 6/15 x 40 (40mm long) - (1 9/32" long)
We can supply other sizes if required.
Concrete hammer screws are available ex-stock from Scotgrip (UK) Ltd.
Securing Scotgrip® anti-slip ladder rung covers with adhesive
The surfaces to be bonded must be dry, clean and grease-free.
Application method (LRCR – round)
- Apply a generous bead to the inside of the ladder rung cover.
- Immediately press the cover to the rung, then pull the cover away and leave both surfaces open for approx. 10-15 minutes. (this will achieve an adhesive transfer and allow quicker solvent evaporation)
- The rung cover can then be placed into position and a contact bond achieved.
Application method (LRCS – square)
- Apply a generous bead to the inside of the ladder rung cover.
- Immediately press the cover firmly to the rung.
Data sheets are available for all adhesives purchased from Scotgrip (UK) Ltd.